What Is the Discovery Patch? A Guide to Non-invasive Sweat Collection for Research 

Sweat carries a wide range of biomarkers and can be collected without a needle. We designed the Discovery Patch to make it a practical and reliable way to collect samples for laboratory research.

Clinical Researcher working

Blood has long been the standard sample for laboratory testing, and with good reason: it provides a detailed view of what is happening in the body. Collecting it, however, requires a needle, a trained phlebotomist and, in most cases, a visit to a clinic or laboratory. For anyone designing a study, those requirements set firm limits on how often participants can be sampled and where that sampling can happen, and those limits can derail a clinical study. 

Sweat offers another route. Over the past decade, research on sweat analysis and wearable biosensors has shown that sweat carries a vast array of electrolytes, metabolites, hormones, proteins and drugs, and that it can be collected without breaking the skin.1 That body of work suggests sweat may hold the key to sampling participants more often, in more settings and with less burden. 

The obstacle has always been sweat collection. As colleagues at Epicore and Northwestern University wrote in Science in 2023, “requirements for specialized equipment, skilled technicians, and strict protocols have limited the broad utility of sweat for routine diagnostics.”1 We built the Discovery Patch to address that obstacle directly. 

What the Discovery Patch is 

The Discovery Patch builds on a decade of work on soft, skin-interfaced microfluidics, much of it developed with John Rogers’ group at Northwestern University. It is a single-use sweat patch for research that captures sweat directly from the skin and holds it for laboratory analysis. After the collection period, a reusable extraction fixture transfers the sweat into a standard storage vial, which can then be analyzed in the research team’s own laboratory or by a third-party laboratory. 

The system is registered with the FDA as a Class I device, exempt from 510(k),2 and we designed it for collecting sweat for biomarker research in both home and professional healthcare settings. 

Discovery Patch or Connected Hydration? 

The first question we work through with most research teams is whether they need a sample or a signal. We develop two wearables that work with sweat, and each offers distinct benefits to a study. For multi-analyte biomarker analysis in a laboratory, the Discovery Patch is the right tool. For live monitoring of hydration and heat stress during a session, Connected Hydration, our wearable biosensor, is the right tool. Larger studies can use both together. 

Discovery Patch Connected Hydration 
Purpose Collects sweat for laboratory analysis Monitors physiology continuously 
Output A sweat sample in a storage vial Live sweat loss, sodium, skin temperature and activity data 
Designed for Biomarker research workflows Hydration and heat-stress applications 
Timing Serial collection at timepoints set by the protocol Continuous throughout a session 
Flowchart for choosing between the Discovery Patch and Connected Hydration. A text version follows.
Text version of this image
  • If your study needs laboratory analysis of sweat biomarkers, such as cytokines, cortisol, proteins or metabolites:
    • and you also need live readings of hydration, sodium or heat stress during the session, use the Discovery Patch and Connected Hydration together.
    • but you don’t need live readings, use the Discovery Patch.
  • If your study doesn’t need laboratory analysis:
    • but you do need live readings of hydration, sodium or heat stress, use Connected Hydration.
    • and you don’t need live readings either, talk to Epicore about your study.

Existing sweat collection methods: strengths and limitations 

Sweat collection for research and clinical testing goes back decades, and each established method has earned its place. Each also carries a known limitation that affects how far the resulting data can be trusted. 

Method Where it works well Key limitation 
Absorbent pads Simple, inexpensive and widely used in sports science Regional pads can overestimate whole-body sodium loss, and pads saturate, so sweat must be recovered from the material before saturation occurs3 
Surface scraping or sealed pouches Require no specialized device Collect compounds already present on the skin; in one metabolomics study, more than half of the metabolites detected came from personal-care products4 
Coil collectors, such as Macroduct The standard collector for the cystic fibrosis sweat test, also called the sweat chloride test Require a trained technician and a clinic visit, and are designed around small volumes, with a 15 µL minimum5 
Whole-body washdown The reference method for total electrolyte loss3 Practical only in a laboratory setting, dilutes the sample, and collects compounds already on the skin or clothing 

A 1985 US military research report put the underlying challenge plainly: “No method has yet been devised for the collection of sweat which has not altered the microenvironment of the collection site.”6 

When we designed the Discovery Patch, our goal was to reduce the main sources of error reported with these methods: contamination from the skin surface, evaporation, loss of sample during recovery, and reliance on trained staff and clinic visits. 

The result is a system with the following features: 

  • FDA registration as a Class I device 
  • A sealed collection path from the skin to the reservoir 
  • Collected volume visible on the patch, up to 410 µL2 
  • Extraction into standard storage vials with a reusable fixture 
  • Samples that can be frozen in the patch for transport 
  • Compatibility with standard laboratory methods, including immunoassays and mass spectrometry 
  • Suitability for both home and professional settings 

How the patch protects sample integrity 

The design rests on a few deliberate choices. 

The collection path is sealed. Sweat enters through an inlet at the skin and travels through a network of microchannels to a reservoir, so the sample has limited exposure to air and to material on the skin surface. That reduces both evaporation and contamination. 

The body fills the patch. The secretory pressure of the sweat glands drives sweat through the channels, so collection is entirely passive.7 

Extraction is mechanical. The patch is placed in a reusable fixture that pushes air through the channels and moves the sweat into a storage vial, a cleaner step than the centrifugation or squeezing used to recover sweat from pads and gauze. 

The patch uses a solid adhesive, which collects the greatest volume in the shortest time. Markings along the channel show the volume collected, up to 410 µL.2 

What the evidence shows about sample quality 

Any reviewer evaluating a collection method will ask three questions: does the sample reflect the underlying biology, does it survive real-world handling, and does the method work outside the laboratory? Published work on the Discovery Patch platform addresses each. 

Does the sample reflect the biology? 

My colleagues and I tested this in a 2021 study published in the Journal of Investigative Dermatology.8 We collected sweat from 10 healthy volunteers in a sauna on 2 consecutive days, using 3 patches on the forearms, and measured the inflammatory cytokines IL-1α and IL-1RA. Concentrations did not depend on the volume of sweat collected, results were consistent between arm sites, and values correlated well from one day to the next. We also saw evening concentrations rise above morning concentrations, which tells us the method is capturing real physiological variation. 

Does the sample survive real-world handling? 

This question matters for any field study, where extracting a sample at the point of collection is often impractical. Kyle Mahoney addressed it in his 2022 thesis at the University of Connecticut.9 Two patches were worn side by side during exercise in a 40°C climate chamber. One was extracted immediately; the other was frozen at −80°C for 48 hours, thawed and then extracted, simulating a sample shipped from a field site. 

Proteomic analysis identified 467 proteins in total. Immediate extraction recovered 434 and the frozen patch recovered 221, with 188 present in both. Of the 467 proteins, only 1 differed significantly in abundance between the two conditions. Mahoney concluded that the patch “offers a feasible system for collecting clean, stable sweat samples.”9 

Our guidance to research teams follows directly from that result. For discovery work, where breadth of coverage matters, extract immediately. When that is not possible, freezing the patch at the point of collection is a sound alternative: fewer proteins are recovered, but the measured abundance of those that are recovered holds. 

Does the method work outside the laboratory? 

In a 2023 proof-of-concept study with the US Anti-Doping Agency, sweat was collected “easily and reliably” from multiple locations on the body, and the samples were suitable for drug analysis.10 Because the Discovery Patch is also intended for home use, it supports decentralized clinical trials and other remote study designs. 

Planning a Discovery Patch study 

Across the studies we support, five questions shape nearly every protocol: 

  • Which analytes are primary, and which are exploratory? 
  • What minimum sample volume does each assay require? 
  • When will samples be collected: at baseline, during an intervention, during recovery or across repeat visits? 
  • How will participants generate sweat? 
  • Does the study require laboratory analysis, live monitoring or both? 

Plan for sweat yield 

Sweat yield is the practical question we discuss most often with research teams, and it is best settled in the protocol. The amount a participant sweats varies with the individual, the environment and the level of activity, so planning should begin with the assay: establish the minimum volume it requires, then design the collection to exceed it reliably. One research team planning a study with us, for example, needed 200 µL to analyze inflammatory microparticles in sweat, comfortably within the patch’s capacity. 

Teams typically generate sweat in one of these ways: 

  • Exercise. In the University of Connecticut work, sessions ran 40 to 120 minutes in a heated chamber.9 
  • Controlled heat. In our Journal of Investigative Dermatology study, participants sat in a sauna at 40 to 45°C for 30 to 45 minutes.8 
  • Pharmacological stimulation, such as pilocarpine iontophoresis, provided separately by the research team. 

Sweat induction is most effective in warm, humid conditions or during exercise. Whichever approach a team chooses, the patch should be applied before sweating begins. 

Follow the sweat collection workflow 

  1. Define the research question and the target analytes. 
  1. Establish the minimum sample volume for each assay and the method participants will use to generate sweat. 
  1. Clean and dry the collection site, then apply the patch before sweating begins. 
  1. Remove the patch after collection and extract the sweat into a storage vial with the reusable fixture, as soon as practical. 
  1. Store and analyze the sample. Extracted sweat can be stored for up to 1 month at −20°C, or longer at −70°C or below,2 and analyzed in-house or by a third-party laboratory. 

Confirm assay feasibility and minimum volume first. Those two factors determine the sweat-generation method, the collection timepoints and the number of patches required. 

Estimate the number of patches 

Multiply the number of participants by the number of collection timepoints and any planned repeats, then add a margin for failed collections and protocol validation. A study of 150 participants with a baseline collection and an exercise collection, for example, requires 300 patches before contingency. If large volumes of sweat are needed, participants can wear multiple patches in different locations for parallel sweat collection. 

From collection to discovery 

A well-collected sample is where good sweat science begins. What researchers can measure in that sample, and how to design studies that get the most from it, is the subject of our companion article by Roozbeh Ghaffari. 

Next step

Planning a study that could use sweat? 

Our team can help you work through analytes, sample volumes and timepoints. 

FAQs


The Discovery Patch is a single-use, soft microfluidic sweat collection patch that captures sweat from the skin for laboratory analysis. After the collection period, a reusable extraction fixture transfers the sweat into a storage vial for testing. It is intended for biomarker research in home and professional healthcare settings. It is a research tool; it is not a drug-testing sweat patch or a diagnostic cystic fibrosis sweat test. 

The Discovery Patch is registered with the FDA as a Class I medical device and is exempt from 510(k) premarket notification. Class I devices are registered with the FDA; approval is a separate pathway that applies to higher-risk devices. 

The Discovery Patch is a collection device, so results come from laboratory analysis of the sample after extraction. For live hydration, sodium loss, skin temperature and heat-stress data, Epicore’s Connected Hydration wearable biosensor is the appropriate tool, and the two can be used together. 

Each patch holds up to 410 µL of sweat, and markings on the patch show the volume collected. The amount a participant provides depends on how much they sweat, so the collection method and duration should be matched to the minimum volume the assay requires. 

Yes. In a University of Connecticut study, patches frozen at −80°C at the point of collection and extracted later recovered fewer proteins than patches extracted immediately, 221 compared with 434, while the abundance of proteins found in both remained nearly identical. Immediate extraction is preferable for discovery work; freezing in the patch is a viable option when immediate extraction is not possible. When freezing a filled patch, we recommend placing it in a resealable bag and removing as much air as possible. 

Sweat generation should be built into the protocol. Common approaches are exercise, controlled heat exposure such as a sauna or climate chamber, and pharmacological stimulation such as pilocarpine iontophoresis, which the research team provides separately. The patch should be applied before sweating begins, and collection time planned around the assay’s minimum volume. 

Multiply the number of participants by the number of collection timepoints, the number of patches worn per participant, and any planned repeats, then add a margin for failed collections and protocol validation. A study of 150 participants with a baseline collection and an exercise collection, for example, requires 300 patches before contingency. 

Yes. The Discovery Patch is intended for home as well as professional healthcare settings, so participants can collect sweat outside the clinic, which suits decentralized clinical trials and hybrid designs. Filled patches can be frozen for transport before extraction, and laboratory results from the samples can be combined with digital biomarkers from wearable biosensors such as Connected Hydration. 

Extracted samples can be stored at −20°C for up to 1 month, or at −70°C or below for longer periods. Sweat should be extracted as soon as practical after the patch is removed, since timing can affect some biomarkers. 

References 

1.  Yang DS, Ghaffari R, Rogers JA. Sweat as a diagnostic biofluid. Science 379(6634):760-761, 2023. doi:10.1126/science.abq5916 

2.  Epicore Biosystems. Discovery Patch Sweat Collection System, Instructions for Use. LBP-01010 Rev 04. 

3.  Baker LB, Stofan JR, Hamilton AA, Horswill CA. Comparison of regional patch collection vs. whole body washdown for measuring sweat sodium and potassium loss during exercise. Journal of Applied Physiology 107(3):887-895, 2009. pubmed.ncbi.nlm.nih.gov/19541738 

4.  Hussain JN, Mantri N, Cohen MM. Working up a good sweat: the challenges of standardising sweat collection for metabolomics analysis. Clinical Biochemist Reviews 38(1):13-34, 2017. pmc.ncbi.nlm.nih.gov/articles/PMC5548369 

5.  Cystic Fibrosis Foundation. Sweat test clinical care guidelines. cff.org/medical-professionals/sweat-test-clinical-care-guidelines 

6.  Defense Technical Information Center. Technical report ADA151916, 1985. apps.dtic.mil/sti/pdfs/ADA151916.pdf 

7.  Soft, skin-mounted microfluidic systems for measuring secretory fluidic pressures generated at the surface of the skin by eccrine sweat glands. Lab on a Chip, 2017. 

8.  Aranyosi AJ, Model JB, Zhang MZ, et al. Rapid capture and extraction of sweat for regional rate and cytokine composition analysis using a wearable soft microfluidic system. Journal of Investigative Dermatology 141(2):433-437, 2021. doi:10.1016/j.jid.2020.05.107 

9.  Mahoney KJ. Stress resilience biomarker discovery using sweat proteomics and novel sweat collection wearable devices. Master of Science thesis, University of Connecticut, 2022. 

10.  US Anti-Doping Agency. Epicore Biosystems and USADA partner on collaboration to deploy sweat-sensing biowearables. February 2024. usada.org/announcement/epicore-biosystems-biowearables-doping-2 

Next step

See what your own crew’s sweat data looks like

One crew, one hot week, measured on the arm. We will read the results with you.