Wearable microfluidic biosensors with haptic feedback for continuous monitoring of hydration biomarkers in workers

Real-time monitoring of hydration biomarkers in tandem with biophysical markers can offer valuable physiological insights about heat stress and related thermoregulatory response. These metrics have been challenging to achieve with wearable sensors.


Author perspective

“The number that stayed with me is 2% body weight loss. For workers performing moderate to intense activity often wearing PPE and often in hot and humid conditions, it is probable that they hit or even exceed this threshold on a weekly or maybe even daily basis. The incident of someone falling off a ladder gets recorded as negligence when the reality might be that they were unsteady or had impaired decision-making skills due to dehydration. Equipping workers with a way to not only monitor their hydration but also provide them personalized, real-time rehydration guidance could make them a more productive worker, reduce heat stress, and potentially prevent accidents and injuries.”

Julia C. Spinelli · Senior Director, Data Science, Epicore Biosystems

Study findings

Thirst is a poor alarm. It barely registers until a person has already lost 1 to 2% of their body mass in fluid, which is the point where physical and cognitive performance start to measurably decline. For someone working in protective equipment in the heat, the signal arrives after the problem does.

This study describes and validates a wearable that measures fluid and sodium loss directly in real time. A reusable electronic module clips into a disposable adhesive patch and is applied to the bicep prior to activity. As the wearer sweats, the conductive fluid moves through the thin microfluidic channel lined with silver chloride electrodes. The electrical signal that is produced provides information about sweat volume, sweat rate, sweat sodium concentration, and total sodium loss. Two temperature sensors and an accelerometer add skin temperature, a heat flux estimate, and activity level.

The device also features a motor that provides the wearer with real-time, tactile vibration alerts and alarms. The device buzzes for 6 seconds for every 500 mL of sweat lost (alert) and vibrates continuously for 20 seconds when net fluid loss reaches 2% of body weight (alarm).

Against laboratory reference methods, the device accurately measured sweat sodium (R² = 0.85) across 13 subjects and whole-body sweat rate (R² = 0.76) across 22 subjects.


Scientific highlights

Sodium and fluid loss, measured continuously

Sweat sodium agreed with a laboratory ion-selective electrode at R² = 0.85 across 13 subjects; whole-body sweating rate agreed with gravimetric body-mass change at R² = 0.76 across 22 subjects.


A buzz on the arm instead of a notification

Six seconds of vibration for every 500 mL of sweat lost, and a continuous 20-second alert at 2% of body weight, so the cue arrives under PPE without the need to view a screen.


Tested under protective clothing in heat

Twenty-two participants wore the device under Nomex coveralls at 30°C and 61% humidity for 60 to 90 minutes at 80% of maximum heart rate.


Over 1000 hours on one coin cell

Enough for months of industrial shift use, with a reusable electronics module and a disposable adhesive microfluidic patch.


Why this research matters

Heat is a measurable safety problem, and not only through heat illness. The paper cites a meta-analysis finding roughly a 1% increase in injuries for each degree Celsius of temperature increase, which puts dehydration and heat strain upstream of incidents that get recorded as something else entirely.

The conventional tools are environmental. A wet bulb globe temperature reading or heat index describes the conditions everyone is standing in but provides no insights into what is happening physiologically to the people exposed to those conditions. Sweat rate and sweat sodium concentration vary widely between individuals doing identical work in identical conditions, which means an environmental threshold protects some workers and leaves others exposed. Measuring the individual allows for personalized hydration guidance.



How this connects to Epicore’s solutions

This is Epicore’s own validation study. Twenty of the 27 authors carry the Epicore affiliation, with first authorship shared by Julia C. Spinelli, Brandon J. Suleski and Donald E. Wright, alongside collaborators at Northwestern, UMass Amherst, the University of Connecticut, Harvard’s Chan School and Rice. It is the peer-reviewed evidence base for Connected Hydration.

The device described here is the research designation of the hardware behind Connected Hydration, including the cloud portal that aggregates fluid loss, sodium loss, skin temperature and activity across a workforce for health and safety managers. The sweat-sensing microfluidics trace back to the same platform as the Gx Sweat Patch, applied to worker safety rather than athletic performance.

Connected Hydration

Real-time sweat and hydration sensing for industrial workers, with personalized intervention before heat stress sets in.


GX Sweat Patch

A wearable microfluidic patch that gives athletes sweat rate and electrolyte feedback to tailor a personalized action plan.


Discovery Patch

An FDA-registered collection system for multi-biomarker sweat analysis in clinical studies, the foundation for cortisol work.

FAQs


There’s no single right answer, which is the problem. Fluid needs depend on sweat rate which varies widely between people doing identical work in identical conditions. General guidance exists, but two workers on the same crew can have very different requirements, so a fixed schedule will overshoot for one and undershoot for the other.

Thirst is a lagging indicator of hydration. Thirst perception is negligible until a person has already lost 1 to 2% of their body mass in fluid, and that’s the same range where physical and cognitive performance begin to decline. By the time you feel thirsty during hard work in the heat, you’re already behind.

Two percent body mass loss is the widely used threshold for meaningful impairment. Physical work capacity and cognitive performance drop, including reaction time and judgment. That second part is what makes it a safety issue rather than only a comfort or performance one, because impaired judgment on a worksite shows up as incidents.

Yes. Weighing before and after activity is the traditional reference method, and it’s accurate but impractical mid-shift. A microfluidic patch captures sweat from a localized area of skin and scales that local measurement to a whole-body estimate. In this study that estimate agreed with the weigh-in method at R² = 0.76 across 22 participants.

Sodium is the main electrolyte lost in sweat, and concentrations vary substantially from person to person, in this study spanning roughly 40 to 115 mM. Genetics, heat acclimatization and diet all contribute to interpersonal differences. Someone with high sweat sodium loses considerably more sodium at the same sweat volume, which is why both fluid and sodium must be considered for proper hydration.

It raises them, and not only through recognized heat illness. This paper cites a meta-analysis finding roughly a 1% increase in injuries per one-degree Celsius increase in temperature. The mechanism runs through fatigue, slower reaction times and degraded judgment, so many heat-driven incidents are recorded under other causes.

Many industrial athletes are not permitted to carry their phones on their person at their work sites and therefore need a wearable that functions in real-time independently of their phone. Even if workers are permitted to have their phone on their person, a worker may be wearing protective clothing, gloves, or hearing protection that might prevent them from interacting with their phone. A vibration on the arm ensures that all workers in all types of PPE and work sites have access to critical hydration alerts.

It can tell you how much fluid and sodium you’ve lost and compare that against your logged intake. In this study, the device issued an alert (short vibration) at each 500 mL of loss and an alarm (long vibration) when a subject lost 2% of their body weight in sweat (>=2% body weight loss is associated with the start of cognitive and physical decline). This study focused on the accuracy of the fluid and sodium loss measurements; any change in hydration behavior that may have resulted from wearing the device were not considered in this study.

Wet bulb globe temperature (WBGT) is the standard occupational heat stress index, combining temperature, humidity, radiant heat, and wind into one number. It’s useful and serves as the basis of most heat safety guidance published by OSHA, NIOSH, and ACGIH. Its limitation is that it describes a generalized area that does not necessarily reflect the micro-environment of the person. An industrial athlete is likely wearing PPE and may be working near equipment that is radiating heat, both of which could increase the micro-climate they are exposed to that a WBGT measurement might not reflect.